Shenzhen Xiaoniu New Energy. Model family XNACS07-GB2015. Firmware DEV_XN2GUN, build 2026-06. The controller drives a left gun and a right gun. Enclosure, input, and connector are the 7 kW AC class. K3 down is 32 A. K3 up is 24 A. The two guns are not added into a 14 kW rating.
| Size | 280 × 400 × 120 mm |
|---|---|
| Ingress | IP54, outdoor |
| Input | AC 220 V 50 Hz, cable 3 × 6 mm² |
| Output | AC 220 V 50 Hz. 32 A and 7 kW with K3 down. 24 A with K3 up |
| Connector | GB/T 20234.2 AC connector, 7 contacts, 3.5 m cable, one left and one right |
| Enclosure | Engineering plastic and tempered glass, flame retardant, UV resistant |
| Network | 4G Cat-1 |
| Payment | WeChat mini program. Prepaid balance, then deducted. A whitelist can charge for free |
| Billing | (energy price + service fee) × energy. Service fee up to 0.8 CNY per kWh |
| Use | Small battery-electric cars and plug-in hybrids. Wall or pedestal. The contactor stays open until a vehicle is connected |
| Life | 8 years |
| MCU | STM32F405. SPI energy meter. Voice, watchdog, and ThingsBoard are built in |
|---|---|
| Guns | Left = 0, right = 1. Attribute sockets is 2. Attribute devtype is 2 |
| Current limit | Each gun starts at 32000 mA until shared attribute imax replaces it. CP PWM is 32/60 of full scale with K3 down, and 24/60 with K3 up |
| Residual current | Each gun has its own detector and self-test. Only the remote command set_EVRCD can skip the test |
| Stop key | Opens the output and stops the charge |
| Holster | Seated on the holder, or lifted off. Separate from the vehicle control-pilot plug-in |
| Temperature | Left gun, board, and right gun, in °C |
| Firmware | fmBuild 2026-06, afrVer 202604-LTS |
Down is open and reads 0. Up is closed and reads 1.
| K1 | Up: plugging in starts the charge when stop is released. Down: wait for switch_ON |
|---|---|
| K2 | Down: buzzer. Up: voice |
| K3 | Down: 32 A / 7 kW. Up: 24 A. Both guns use the same setting |
| K4 | Down: MQTT over TLS, port 8883. Up: plaintext MQTT, port 1883. Broker is mqtt.thingsboard.cloud |
Attribute boardKeys: bits 0–3 are K1–K4. Bit 4 is left-gun enable. Bit 5 is right-gun enable.
The charger provisions itself. The MQTT username is provision. The device name is the 12-hex MAC. After provisioning it stores the negotiated username and password, reboots, and publishes. Shared imax is two current limits in milliamps. powrate is the meter constant and starts at 100.
Published when a value changes. Voltage in V, current in mA, energy in Wh, power in W, temperature in °C.
| Each gun | _voltageL _voltageR voltage_curL _curR current_energyL _energyR energy_powL _powR power_stateL _stateR charge state_stpL _stpR stop reason_swtL _swtR output switch_cpL _cpR control pilot, positive half_czL _czR control pilot, negative half_pwmL _pwmR CP pulse width_holsterL _holsterR holster |
|---|---|
| Charger | _tmpL _tmpB _tmpR temperature_volgnd line-to-ground voltage_stopkey emergency stop_lteSign LTE signal_fastloads fast-report count remaining |
Gun voltage stays 0 while the contactor is open. Line-to-ground voltage is still reported. The charger also sends evt_gunCHANGE (2 left in, 3 right in, 4 left out, 5 right out), evt_holsterCHANGE (6 left seated, 7 left lifted, 8 right seated, 9 right lifted), and evt_rptavgpow.
Two-way RPC. Each call carries one parameter, params.value, and replies with the method and the value applied. Gun numbers are 0 for left and 1 for right.
switch_ON | 0 or 1. Starts the charge sequence on that gun. With no vehicle connected the sequence runs and the contactor stays open |
|---|---|
switchOFF | 0 or 1. Stops that gun at once, sets stop reason 9 (stopped from the dashboard), sets its current limit to 0 and opens its contactor and control pilot |
all_ONOFF | 1 starts both guns that are idle. 0 stops both guns with stop reason 9. Values above 1 are read as 1 |
pwm_gl_EN, pwm_gr_EN | Control-pilot duty in 0.1 %, 1–990, for the left or right gun. 100 is 10 %, about 6 A; 533 is about 32 A. Any value above 990, for example 999, closes the output |
beepTIMES | style × 10 + count, for example 3 or 26. Plays count beeps with the pattern chosen by style; count 0 plays one beep |
to_reload | 0–160, larger values are capped. Sends up to that many telemetry reports in quick succession, so a dashboard refreshes at once |
reboot_me | A reason code: 14 server request, 15 share-page request, 16 assistant request. Replies, then reboots at once and records the code as the boot reason; any other value is recorded as a generic server reboot. Charging stops |
firmw_OTA | Any value, normally 1. Acknowledges with 1 and beeps twice. It does not start a download by itself: firmware is installed through ThingsBoard's own OTA updates. Assigning firmware sets the shared attributes fw_title, fw_version and fw_size, and the charger downloads the image in chunks and reboots into it |
firmwOTA2 | A plain http:// URL, 11 to 126 characters. Stores the URL, sets the update flag and reboots into the boot loader, which downloads and installs that firmware. A value that is not a plain http:// URL of that length clears the update flag and changes nothing; the reply then carries the current application version |
off_TMOUT | 0 or 1. Stops that gun with stop reason 4 (normal stop). A billing server sends it when the paid time ends |
off_NOMEY | 0 or 1. Stops that gun with stop reason 5 (prepaid balance exhausted) |
get_SW_ST, get_CURET, get_STOPF, get_AVGP | 0 or 1. Read back the output switch, the current, the stop reason or the average power |
reset_all | Erases the stored settings, provisioning included, and reboots. Do not put it on a dashboard |
Set these on the device from the server. The charger reads them at power-on and applies a pushed change immediately; both survive a power cycle.
imax | A JSON array of two integers in milliamps, left gun first: [16000, 24000]. Current limit of each gun, stored separately; 0 leaves that gun on the default limit. K3 still sets the hardware ceiling, 32 A or 24 A. It is JSON, not a string |
|---|---|
powrate | One integer, 100 at the factory. Meter constant of the SPI energy meter |