XNBK12 12-Outlet E-Bike Charger

Shenzhen Xiaoniu New Energy. Model family XNBK12. Firmware DEV_12_BIKE, build 2026-06. One cabinet feeds 12 outlets. The vehicle keeps its own charger. This cabinet does not raise the charge rate.

1. Charger

VehiclesE-bikes, e-motorcycles, electric tricycles, and low-speed four-wheelers
Size280 × 400 × 120 mm
IngressIP54, outdoor
InputAC 220 V 50 Hz, cable 3 × 10 mm²
Cabinet power11 kW
Output12 of 86 mm, 220 V sockets. Live wires 2.5 mm² × 12. Neutral 4 mm² × 1
Recognition0 to 900 W, automatic
EnclosureEngineering plastic and tempered glass, flame retardant, UV resistant
Network4G Cat-1
PaymentWeChat mini program. Prepaid balance, then deducted. A whitelist can charge for free
BillingBy measured power band, per minute. The backend can change the bands. Reference: 1–150 W 0.3 CNY/hour, 151–250 W 0.4, 251–350 W 0.6, 351–500 W 0.8, 501–700 W 1.1, 701–900 W 1.5
SafetyOpens on a full battery, opens when the plug is pulled, and the socket is dead when idle
ComplianceDesigned to GB 4706.1 and tested by a national laboratory
InstallCabinet and sockets on a wall, on a shelter post, or with the sockets on their own posts
Life8 years

2. Controller

MCUSTM32F405. SPI meter for the cabinet total and the 12 branch currents. Voice, watchdog, and ThingsBoard are built in
Outlets0 to 11. Attribute sockets is 12. Attribute devtype is 4
Current ceilingEach outlet starts at 8000 mA until shared attribute imax replaces it. K1 up raises the local hard ceiling to 13000 mA. K1 down keeps 8000 mA. This ceiling is protection. It is not the 0–900 W recognition range
PowerK3 down scales voltage × current by the cabinet active-power ratio. K3 up uses voltage × current directly
TemperatureLeft, board, and right. Over-temperature opens all 12 outlets. Telemetry is °C
FirmwarefmBuild 2026-06, afrVer 202604-LTS

3. DIP switches

Down is open and reads 0. Up is closed and reads 1.

K1Down: 8 A hard ceiling per outlet. Up: 13 A hard ceiling per outlet
K2Down: buzzer. Up: voice, including the outlet number when an outlet closes
K3Down: active-power correction. Up: voltage times current
K4Down: MQTT over TLS, port 8883. Up: plaintext MQTT, port 1883. Broker is mqtt.thingsboard.cloud

Attribute boardKeys: bits 0–3 are K1–K4.

4. Cloud

The cabinet provisions itself. The MQTT username is provision. The device name is the 12-hex MAC. After provisioning it stores the negotiated username and password, reboots, and publishes. Shared imax is 12 current limits in milliamps. powrate is the meter constant and starts at 100.

The ThingsBoard IoT Hub package creates the device profile XNBK12 12-Outlet E-Bike Charger and the dashboard 12-Outlet E-Bike Charger.

5. Telemetry

Published when a value changes. Cabinet voltage in V, total current in mA, total energy in Wh. Branch current in mA, branch power in W.

Cabinet_voltage line-to-neutral voltage
_current total current
_energy total energy
_tmpL _tmpB _tmpR temperature
_lteSign LTE signal
_fastloads fast-report count remaining
Outlets 0–11_swt0 … _swt11 output switch
_cur0 … _cur11 current
_pow0 … _pow11 power
_stp0 … _stp11 stop reason

During a charge the cabinet sends evt_rptavgpow with the total and the 12 branch averages. When the cabinet itself opens an outlet it sends evt_switchOFF.