Shenzhen Xiaoniu New Energy. Model family XNBK12. Firmware DEV_12_BIKE, build 2026-06. One cabinet feeds 12 outlets. The vehicle keeps its own charger. This cabinet does not raise the charge rate.
| Vehicles | E-bikes, e-motorcycles, electric tricycles, and low-speed four-wheelers |
|---|---|
| Size | 280 × 400 × 120 mm |
| Ingress | IP54, outdoor |
| Input | AC 220 V 50 Hz, cable 3 × 10 mm² |
| Cabinet power | 11 kW |
| Output | 12 of 86 mm, 220 V sockets. Live wires 2.5 mm² × 12. Neutral 4 mm² × 1 |
| Recognition | 0 to 900 W, automatic |
| Enclosure | Engineering plastic and tempered glass, flame retardant, UV resistant |
| Network | 4G Cat-1 |
| Payment | WeChat mini program. Prepaid balance, then deducted. A whitelist can charge for free |
| Billing | By measured power band, per minute. The backend can change the bands. Reference: 1–150 W 0.3 CNY/hour, 151–250 W 0.4, 251–350 W 0.6, 351–500 W 0.8, 501–700 W 1.1, 701–900 W 1.5 |
| Safety | Opens on a full battery, opens when the plug is pulled, and the socket is dead when idle |
| Compliance | Designed to GB 4706.1 and tested by a national laboratory |
| Install | Cabinet and sockets on a wall, on a shelter post, or with the sockets on their own posts |
| Life | 8 years |
| MCU | STM32F405. SPI meter for the cabinet total and the 12 branch currents. Voice, watchdog, and ThingsBoard are built in |
|---|---|
| Outlets | 0 to 11. Attribute sockets is 12. Attribute devtype is 4 |
| Current ceiling | Each outlet starts at 8000 mA until shared attribute imax replaces it. K1 up raises the local hard ceiling to 13000 mA. K1 down keeps 8000 mA. This ceiling is protection. It is not the 0–900 W recognition range |
| Power | K3 down scales voltage × current by the cabinet active-power ratio. K3 up uses voltage × current directly |
| Temperature | Left, board, and right. Over-temperature opens all 12 outlets. Telemetry is °C |
| Firmware | fmBuild 2026-06, afrVer 202604-LTS |
Down is open and reads 0. Up is closed and reads 1.
| K1 | Down: 8 A hard ceiling per outlet. Up: 13 A hard ceiling per outlet |
|---|---|
| K2 | Down: buzzer. Up: voice, including the outlet number when an outlet closes |
| K3 | Down: active-power correction. Up: voltage times current |
| K4 | Down: MQTT over TLS, port 8883. Up: plaintext MQTT, port 1883. Broker is mqtt.thingsboard.cloud |
Attribute boardKeys: bits 0–3 are K1–K4.
The cabinet provisions itself. The MQTT username is provision. The device name is the 12-hex MAC. After provisioning it stores the negotiated username and password, reboots, and publishes. Shared imax is 12 current limits in milliamps. powrate is the meter constant and starts at 100.
The ThingsBoard IoT Hub package creates the device profile XNBK12 12-Outlet E-Bike Charger and the dashboard 12-Outlet E-Bike Charger.
Published when a value changes. Cabinet voltage in V, total current in mA, total energy in Wh. Branch current in mA, branch power in W.
| Cabinet | _voltage line-to-neutral voltage_current total current_energy total energy_tmpL _tmpB _tmpR temperature_lteSign LTE signal_fastloads fast-report count remaining |
|---|---|
| Outlets 0–11 | _swt0 … _swt11 output switch_cur0 … _cur11 current_pow0 … _pow11 power_stp0 … _stp11 stop reason |
During a charge the cabinet sends evt_rptavgpow with the total and the 12 branch averages. When the cabinet itself opens an outlet it sends evt_switchOFF.